We accept Visa and Mastercard

 HiPot Testers

Testwave LLC® has been selling, renting and servicing Hipot Products for over eight years.


Testwave Technical Tip: Any tool which is found to have leakage current in excess of 0.5 milliamperes should be immediately identified with a red tag as unsafe, and repaired by qualified personnel in accordance with the manufacturer’s recommendations prior to returning to service.

Slaughter Model 2512 2.5kVAC Hipot with ground continuity

A Picture of the Slaughter Model 2512 2.5kVAC Hipot with ground continuity.
  • Output voltage, accuracy, resolution: 0V-2.50KVAC, 10 volts/step, ±(1% of output plus 5 volts), 10V/step
  • Dielectic trip limit (failure setting), accuracy: 0.1-100mA 0.1mA/step, ±(2% of setting +0.05mA)
  • Three dwell settings: Continuous, one second test, sixty seconds test
  • Ramp settings and resolution: 0.1 second fixed ramp and 0.2 - 999.9 seconds, 0.1 second/step
  • Timer display, resolution, accuracy: 0.0-999.9 seconds, 0.1 second, ±(0.2% of reading +0.05 seconds)
  • Test / Reset: Buttons on front panel
  • Back panel, two DB-9 male connectors, and ground sense
    • Remote inputs:Test and reset
    • Signal outputs: Pass, fail and test in progress
    • Optional remote receptable box sensing circuit (for line cord connected devices)
  • Microprocessor based with LED display: Four front panel buttons control the menu and settings
  • Instrument settings: Powers up with the last settings to avoid operator setup errors
  • Input voltage, fuse: 115/230 selectable ±15% variation 47-63Hz, 15A fast acting
  • Size and weight: 17.0x5.25x11.75 inches (430x133x300 mm), 43 lbs (20 Kgs)
  • Environmental operating temperature, humidity: 32-104ºF (0 to 40ºC), 0-80% non-condensing
  • Complete with 6 foot high-voltage safety probe, 6 foot high-voltage clip, 6 foot ground return, 6 foot NEMA detachable line cord, user manual, and calibration certificate
    • For rent only, please call for pricing.

Slaughter Model 2945 5kVAC, 6kVDC Hipot with IR and ground continuity

A Picture of the Slaughter Model 2945 5kVAC, 6kVDC Hipot with IR and ground continuity
  • AC output voltage, accuracy, resolution: 0-5kV, ±(1% of output +5V), 2V/step
  • DC output voltage, resolution, accuracy: 0-6kV, 2V/step, ±(1% of output +5V)
  • AC dielectic trip limit (failure setting), resolution, accuracy : High Limit: 0.10-12.00mA, 0.01 mA/step, ±(2% of setting +0.02mA); Low Limit: 0.00, 0.10-12.00 mA, 0.01 mA/step, ±(2% of setting +0.02mA)
  • DC dielectic trip limit (failure setting), accuracy: High Limit: 0.02-5.00mA, 0.01 mA/step, ±(2% of setting +0.02mA); Low Limit: 0.00, 0.02-5.00 mA, 0.01 mA/step, ±(2% of setting +0.02mA)
  • Timer display, resolution, accuracy: 0.0-999.9 seconds, 0.1 second, ±(0.1% of reading +0.05 seconds)
  • Ramp settings and resolution: 0.1 second fixed ramp and 0.2 - 999.9 seconds, 0.1 second/step
  • Instrument Settings: Powers up with the last settings to avoid operator setup errors
  • Microprocessor based with LCD display: Four front panel buttons control the menu and settings
  • Test / Reset: Buttons on front panel
  • Back panel I/O, one DB-9 male connector
    • Remote control inputs: Test and reset
    • Signal outputs: Pass, fail and test in progress
  • Environmental operating temperature, humidity: 32-113ºF (0 to 45ºC), 0-95% non-condensing
  • Size and weight: 11x3.5x14.56 inches (280x89x370 mm), 20 lbs (9 Kgs)
  • 5 foot high voltage clip, 5 foot ground return, detachable 7 foot line cord, user manual, and calibration certificate. Optional box may be purchased for testing items with a line cord
    • For rent only, please call for pricing.

 

INSTEK GPT 815 Electrical Safety Tester

 FEATURES

500VA AC output

True RMS Current read-back

Arc Detection

Easy Operation

3 ranges of adjustable cut-off current 

Digital display for voltage, current and timer at same time

Zero Crossing Turn-On (for GPT-805/815, GPI-825)

Automatic FAIL indicator of alarm lamp and buzzer

9 Pin PLC Control for Start, Stop and Test Result Output

General input power acceptable

Voltage output adjustable during test period

Down Load GPT 815 Specifications

 


You can continue to count on us to bring you quality test equipment at practical prices. If you are looking for a used Hipot tester, see Rental and Sales, or for calibration Click here.

Thank you for your business!


Testwave LLC®
1461 Greg Street
Sparks, NV 89431-5915

Phone and Fax Country Code 001
Phone 775-356-8378
Fax 775-356-8290

Hours: Mon - Fri 9 a.m. to 5 p.m. PST

eMail: help@testwave.com


Copyright © 2005-2017 Testwave, LLC
All Rights Reserved.
The date on this page is taken from your computer.